  Datasheet File OCR Text:
   power entry modules with line filter FKH www.schurter.com/pg0 6 emc products iec appliance inlet c14 with filter, fuseholder 1-pole, line switch 2-pole on phase-out standard- or medical-filter c14 70 c description - panel mount: screw-on mounting from front side - 4 functions: appliance inlet protection class i, line switch 2-pole, fuseholder for fuse-links 5 x 20 mm 1-pole, line-filter in standard version - quick connect terminals 6.3 x 0.8 mm approvals - vde license number: 40004665 - ul license number: e72928 characteristics - compact design with optimal shielding - all single elements are already wired - plug removal necessary for fuse-link replacement if the power entry module is installed as normal, it is not possible to touch any live parts with the test-finger according to iec60529 fuse drawer meets requirements of medical standard iec/en 60601-1 the fuseholder is accessible from the equipment front - with emc-shield - qualified for use in equipment according iec/en 60950 other versions on request - medical version m80 references general product informatio n weblinks approval s , roh s , china-roh s , mating connector s , distributor-stock- chec k , accessorie s technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 10 a @ ta 40 c / 125 vac; 60 hz leakage current standard < 0.25 ma (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 6.3 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1-pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 mm rated power acceptance @ ta 23 c 5 x 20: 1.6 w (1 pole) power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line switch rocker switch 2-pole, non-illuminated, acc. to iec 61058-1 technical detail s line filter standard version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 1'700'000 h acc. to mil-hb-217 f
 power entry modules with line filter FKH www.schurter.com/pg0 6 emc products dimensions 55 mm case 45 recommend for new designs 40 49.5 40 r1 6.3x0.8 0.5 0.5 28 63 65 r3 61.5 50 0.5 50 67 28.7 0.5 0.5 5.5 14 29.5 3.5 ? 3.2 ? 5.8x90 60.2 61 0.15 m3 case 50 on phase-out 40 49.5 40 r1 6.3x0.8 0.5 0.5 28 63 65 r3 41 50 0.5 50 55 28.7 0.5 0.5 5.5 15 29.5 3.5 ? 3.2 ? 5.8x90 60.2 61 0.15 m3 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 10 68 2.2 1 2 standard version 2 x 4 68 2.2 1 4 standard version 2 x 1.5 68 2.2 1 6 standard version 2 x 0.8 68 2.2 1 10 standard version 2 x 0.3 68 2.2 1 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1 10 medical version (m5) 2 x 0.3 68 - 1
 power entry modules with line filter FKH www.schurter.com/pg0 6 emc products diagrams standard version 1) line 2) only fki 3) load medical version n pe l cx l1 l2 n? pe ? l? r cx f2 f1 1) 2) 1) line 2) load derating curves 1-pole admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 100 0.2 0.0 i = < < i n i = 0.7 i n i = 1.0 i n 1.6 0.6 0.4 0.8 1.2 1.0 1.4 ambient air temperature ta c attenuation loss - - - - differential mode _____ common mode standard version 1 a 2 a 4 a 6 a 10 a medical version (m5) 1 a 2 a 4 a 6 a 10 a technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 10 68 2.2 1 2 standard version 2 x 4 68 2.2 1 4 standard version 2 x 1.5 68 2.2 1 6 standard version 2 x 0.8 68 2.2 1 10 standard version 2 x 0.3 68 2.2 1 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1 10 medical version (m5) 2 x 0.3 68 - 1
 power entry modules with line filter FKH www.schurter.com/pg0 6 emc products variants socket and fuse drawer included type rated current [a] filter-type fuseholder line switch housing material: housing comment order number FKH 1 standard version 1-pole 2-pole 45 aluminum - 4304.4041 FKH 2 standard version 1-pole 2-pole 45 aluminum - 4304.4042 FKH 4 standard version 1-pole 2-pole 45 aluminum - 4304.4043 FKH 6 standard version 1-pole 2-pole 45 aluminum - 4304.4044 FKH 10 standard version 1-pole 2-pole 45 aluminum - 4304.4045 FKH 1 medical version (m5) 1-pole 2-pole 45 aluminum - 4304.4046 FKH 2 medical version (m5) 1-pole 2-pole 45 aluminum - 4304.4047 FKH 4 medical version (m5) 1-pole 2-pole 45 aluminum - 4304.4048 FKH 6 medical version (m5) 1-pole 2-pole 45 aluminum - 4304.4049 FKH 10 medical version (m5) 1-pole 2-pole 45 aluminum - 4304.4050 FKH 1 standard version 1-pole 2-pole 50 nickel plated steel 1) 4304.4001 FKH 2 standard version 1-pole 2-pole 50 nickel plated steel 1) 4304.4002 FKH 4 standard version 1-pole 2-pole 50 nickel plated steel 1) 4304.4003 FKH 6 standard version 1-pole 2-pole 50 nickel plated steel 1) 4304.4004 FKH 10 standard version 1-pole 2-pole 50 nickel plated steel 1) 4304.4005 1) versions with nickel plated steel enclosure are on phase-out. for new designs we recommend the versions with aluminum enclosure. packaging unit 10 pcs accessorie s description assorted cover s rear cover 0859.0074 mating outlets/connector s category / description appliance outlet overview complet e iec appliance outlet f, screw-on mounting, front side, solder or quick-connect terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outlet further types to fk h connector overview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connector further types to fk h ...
 power entry modules with line filter FKH www.schurter.com/pg0 6 emc products category / description power cord overview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cord further types to fk h ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.